53 research outputs found
Centrifugal separation and equilibration dynamics in an electron-antiproton plasma
Charges in cold, multiple-species, non-neutral plasmas separate radially by
mass, forming centrifugally-separated states. Here, we report the first
detailed measurements of such states in an electron-antiproton plasma, and the
first observations of the separation dynamics in any centrifugally-separated
system. While the observed equilibrium states are expected and in agreement
with theory, the equilibration time is approximately constant over a wide range
of parameters, a surprising and as yet unexplained result. Electron-antiproton
plasmas play a crucial role in antihydrogen trapping experiments
Antihydrogen and mirror-trapped antiproton discrimination: Discriminating between antihydrogen and mirror-trapped antiprotons in a minimum-B trap
Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum
(minimum-B) trap formed by superconducting octupole and mirror magnet coils.
The trapped antiatoms were detected by rapidly turning off these magnets,
thereby eliminating the magnetic minimum and releasing any antiatoms contained
in the trap. Once released, these antiatoms quickly hit the trap wall,
whereupon the positrons and antiprotons in the antiatoms annihilated. The
antiproton annihilations produce easily detected signals; we used these signals
to prove that we trapped antihydrogen. However, our technique could be
confounded by mirror-trapped antiprotons, which would produce
seemingly-identical annihilation signals upon hitting the trap wall. In this
paper, we discuss possible sources of mirror-trapped antiprotons and show that
antihydrogen and antiprotons can be readily distinguished, often with the aid
of applied electric fields, by analyzing the annihilation locations and times.
We further discuss the general properties of antiproton and antihydrogen
trajectories in this magnetic geometry, and reconstruct the antihydrogen energy
distribution from the measured annihilation time history.Comment: 17 figure
Alpha Antihydrogen Experiment
ALPHA is an experiment at CERN, whose ultimate goal is to perform a precise
test of CPT symmetry with trapped antihydrogen atoms. After reviewing the
motivations, we discuss our recent progress toward the initial goal of stable
trapping of antihydrogen, with some emphasis on particle detection techniques.Comment: Invited talk presented at the Fifth Meeting on CPT and Lorentz
Symmetry, Bloomington, Indiana, June 28-July 2, 201
Search For Trapped Antihydrogen
We present the results of an experiment to search for trapped antihydrogen
atoms with the ALPHA antihydrogen trap at the CERN Antiproton Decelerator.
Sensitive diagnostics of the temperatures, sizes, and densities of the trapped
antiproton and positron plasmas have been developed, which in turn permitted
development of techniques to precisely and reproducibly control the initial
experimental parameters. The use of a position-sensitive annihilation vertex
detector, together with the capability of controllably quenching the
superconducting magnetic minimum trap, enabled us to carry out a
high-sensitivity and low-background search for trapped synthesised antihydrogen
atoms. We aim to identify the annihilations of antihydrogen atoms held for at
least 130 ms in the trap before being released over ~30 ms. After a three-week
experimental run in 2009 involving mixing of 10^7 antiprotons with 1.3 10^9
positrons to produce 6 10^5 antihydrogen atoms, we have identified six
antiproton annihilation events that are consistent with the release of trapped
antihydrogen. The cosmic ray background, estimated to contribute 0.14 counts,
is incompatible with this observation at a significance of 5.6 sigma. Extensive
simulations predict that an alternative source of annihilations, the escape of
mirror-trapped antiprotons, is highly unlikely, though this possibility has not
yet been ruled out experimentally.Comment: 12 pages, 7 figure
Trapped antihydrogen
Precision spectroscopic comparison of hydrogen and antihydrogen holds the promise of a sensitive test of the Charge-Parity-Time theorem and matter-antimatter equivalence. The clearest path towards realising this goal is to hold a sample of antihydrogen in an atomic trap for interrogation by electromagnetic radiation. Achieving this poses a huge experimental challenge, as state-of-the-art magnetic-minimum atom traps have well depths of only ∼1T (∼0.5K for ground state antihydrogen atoms). The atoms annihilate on contact with matter and must be ‘born' inside the magnetic trap with low kinetic energies. At the ALPHA experiment, antihydrogen atoms are produced from antiprotons and positrons stored in the form of non-neutral plasmas, where the typical electrostatic potential energy per particle is on the order of electronvolts, more than 104 times the maximum trappable kinetic energy. In November 2010, ALPHA published the observation of 38 antiproton annihilations due to antihydrogen atoms that had been trapped for at least 172ms and then released—the first instance of a purely antimatter atomic system confined for any length of time (Andresen etal., Nature 468:673, 2010). We present a description of the main components of the ALPHA traps and detectors that were key to realising this result. We discuss how the antihydrogen atoms were identified and how they were discriminated from the background processes. Since the results published in Andresen etal. (Nature 468:673, 2010), refinements in the antihydrogen production technique have allowed many more antihydrogen atoms to be trapped, and held for much longer times. We have identified antihydrogen atoms that have been trapped for at least 1,000s in the apparatus (Andresen etal., Nature Physics 7:558, 2011). This is more than sufficient time to interrogate the atoms spectroscopically, as well as to ensure that they have relaxed to their ground stat
Experimental and computational study of the injection of antiprotons into a positron plasma for antihydrogen production
One of the goals of synthesizing and trapping antihydrogen is to study the validity of charge-parity-time symmetry through precision spectroscopy on the anti-atoms, but the trapping yield achieved in recent experiments must be significantly improved before this can be realized. Antihydrogen atoms are commonly produced by mixing antiprotons and positrons stored in a nested Penning-Malmberg trap, which was achieved in ALPHA by an autoresonant excitation of the antiprotons, injecting them into the positron plasma. In this work, a hybrid numerical model is developed to simulate antiproton and positron dynamics during the mixing process. The simulation is benchmarked against other numerical and analytic models, as well as experimental measurements. The autoresonant injection scheme and an alternative scheme are compared numerically over a range of plasma parameters which can be reached in current and upcoming antihydrogen experiments, and the latter scheme is seen to offer significant improvement in trapping yield as the number of available antiprotons increases
Autoresonant-spectrometric determination of the residual gas composition in the ALPHA experiment apparatus
Knowledge of the residual gas composition in the ALPHA experiment apparatus is important in our studies of antihydrogen and nonneutral plasmas. A technique based on autoresonant ion extraction from an electrostatic potential well has been developed that enables the study of the vacuum in our trap. Computer simulations allow an interpretation of our measurements and provide the residual gas composition under operating conditions typical of those used in experiments to produce, trap, and study antihydrogen. The methods developed may also be applicable in a range of atomic and molecular trap experiments where Penning-Malmberg traps are used and where access is limited
Microwave Spectroscopy of Magnetically Trapped Atomic Antihydrogen
We have every reason to believe that equal amounts of matter and antimatter were produced in the early universe. Moreover, theory predicts that the laws of physics make no distinc- tion between the two. In this light, the fact that the observable universe is overwhelmingly dominated by matter is inexplicable. ALPHA is an international project located at CERN involving approximately 40 physi- cists from 15 different institutions in 7 countries. The primary goal of the collaboration is to study the antihydrogen atom at the highest level of precision possible, and thereby enable comparisons between hydrogen and antihydrogen. Through these comparisons it hopes to improve our understanding of the distinction between matter and antimatter, and perhaps shed some light on the puzzle of why we live in a matter dominated universe. The hyperfine energy intervals of ground-state hydrogen and antihydrogen represent an opportunity for a precision comparison. A discrepancy between the energy levels of these two atomic sys- tems would indicate a major revolution in physics, and in our understanding of the universe. This thesis describes and interprets the first proof-of-principle spectroscopic measure- ments performed on magnetically trapped antihydrogen atoms. The experiments were per- formed by the ALPHA collaboration using microwave radiation tuned to induce transitions between hyperfine levels of ground state antihydrogen atoms. Our observations confirm that positron spin resonance transitions between hyperfine levels of ground state antihydro- gen are consistent with expectations for hydrogen to within 4 parts in 103. The hyperfine splitting of ground state antihydrogen atoms is also constrained to 1420 ± 85 MHz
E-bus Opportunity Charging System Supplied by Tramway Line: A Real Case Study
The introduction of a tramway DC grid to support multiple E-Bus fast opportunity charging points is the main topic of this article. After that, a voltage balancing system is developed and tested for this model to resolve the problem of voltage instability brought on by trams' braking and speeding, and subsequently, to improve the operation of opportunity charging points. The voltage balancing block in this concept uses a battery backup system that is coupled to the DC tram network via a reversible dual active bridge (DAB) DC/DC converter to maintain the voltage within a preset band (550- 630V DC). In this work, a single-phase shift control method is used to adjust the amount and direction of the power by applying a variable time delay to the gate signals of the IGBTs in the converter. The effectiveness of such a system is simulated and assessed in MATLAB/Simulink during the course of the tram's journey through two stations
- …